It's a small sample—just 0.6 microliter.

The system automatically detects when enough blood has been applied to the strip and begins the test, even if some yellow is still visible. The only time you need to apply more blood is when the blood drop symbol continues to flash in the display.

An E4 displays on the meter, indicating not enough blood was drawn into the test strip for measurement or blood was applied after the test had started. You should discard the test strip and repeat the blood sugar test. 

Yes. In addition to the fingertip, you can collect blood samples from the palm, forearm or upper arm. Talk with your healthcare professional before deciding if alternate site testing is right for you.

Your Accu-Chek lancing device has a special plastic cap designed for testing on other areas of the body. Talk with your healthcare professional before deciding if alternate site testing is right for you.

Note: Do not use the special plastic cap when testing at the fingertip. Follow the steps for fingertip testing, with a few differences:

  • Use the clear or gray cap.
  • You may need a deeper setting. Try 3 for palm testing or 5-1/2 for forearm or upper arm testing. (These are suggested settings; yours may differ.)
  • Press the opening of the clear or gray cap firmly against a fleshy area of the non-fingertip site. Press the lancing device up and down in a slow pumping motion to assist the flow of blood.
  • Keep steady pressure on the area, then press and release the plunger. Do not be afraid to apply pressure to the area with the lancing device to assist the flow of blood. Continue to press the cap against the site for a few seconds to allow blood to come to the surface.

Meter care and battery

Clean and disinfect your meter once a week, or any time blood gets on the meter. You should also clean the meter before allowing anyone else to handle it.

Cleaning is simply removing dirt from the meter, while disinfecting refers to removal of most but not all, disease-causing and other types of microorganisms.

  • 70% isopropyl alcohol
  • Mild dishwashing liquid mixed with water
  • 10% household bleach solution (1 part bleach plus 9 parts water) made the same day

Be sure to clean the areas around slots and openings, while being careful not to get any moisture in them. You should also wipe down the entire meter surface, including the meter display.

Visit your meter's Screen Messages page for a list of messages and definitions or download the User Manual (insert appropriate link) for your meter.

Test Strips and control tests

No. Accu-Chek Aviva blood glucose meters are designed exclusively for use with Accu-Chek Aviva test strips.

No, check the use by date on the test strip container. Do not use test strips past the use by date.

VIEW ALL FAQs
Still can't find what you need?

We want your feedback!

GO

 

 

Accu-Chek Aviva

Item Description

The Accu-Chek Aviva blood glucose meter makes testing your blood sugar quick and easy. It’s ready to use right out of the box, requiring no set-up. Each meter uses Accu-Chek Aviva test strips and an Accu-Chek lancing device. Helpful alerts remind you to test before and after meals, giving you valuable information to support therapy decisions for a healthy active life.

Product Manuals

DISPLAY

Large LCD

RESULTS

5 seconds

EASY

No coding. No set-up.

SAMPLE

Tiny: 0.6µL

WEIGHT

59g with battery

Benefits and Features
  • Large, easy-to-read LCD display
  • Used with easy-to-handle Accu-Chek® Aviva test strips
  • An Accu-Chek lancing device may be purchased separately
  • Tiny blood sample: only 0.6µL of blood required
  • Fast results in 5 seconds
  • No coding needed, making the testing process quicker and easier
  • No set-up required. It’s ready to use right out of the box.
  • Set up to 4 pre- or post-meal alerts, so you never forget to test
  • Automatically turns on when you insert a test strip
  • Saves energy by turning off automatically when you’re finished testing
  • Time and memory are saved for up to 72 hours if the battery is removed
Additional specifications
Serial number:

Unique serial number printed on a label on the device and stored in non-volatile memory

Measuring principle:

Mutant variant of quinoprotein glucose dehydrogenase (Mut. Q-GDH), electrochemical

Measuring time:

Approximately 5 seconds

Measuring conditions:

Temperature: 8°C to 44°C (46°F to 111°F)

Storage conditions:

-25°C to + 70°C (-13°F to +158°F)

Memory capacity:

Up to 500 total results, plus 20 control tests

Test averages:

7, 14, 30 and 90 days

Data transfer:

Infrared (IR)

How to use the Accu-Chek Aviva blood glucose meter

Get accurate results in 3 steps:

  • Insert your test strip into the meter and it turns on automatically.
  • Apply your blood sample to the easy-to-see yellow window. Only 1 small drop is needed.
  • In approximately 5 seconds, your test results will appear in the easy-to-read display.